Technica Data
| Maxima Tensio Operativa Continua | (AC)Uc | 275V | 320V | 385V | 440V |
| Tensio Aestimata | (AC)Un | 220V | 220V | 220V | 220V |
| Currens nominalis exonerationis (T2) | In | 20kA | 20kA | 20kA | 20kA |
| Maxima fluxus emissionis | Imax | 40kA | 40kA | 40kA | 40kA |
| Gradus tutelae | Up | 0.8 | 1.0 | 1.0 | 1.2 |
| Sequere Aestimationem Interruptionis Currentis | I | NULLUM | |||
| Tempus Responsionis | tA | Centum ns | |||
| SPDDisjunctor specialis | Suadeo | SSD40 | |||
| TOV | N-PE | 1200V | |||
| Currens residuus - Currens effluxio apud | lpe | NULLUM | |||
| Currentis brevis circuitus admissibilis | Isccr | 25000A | |||
| Communicatio remota | Cum | ||||
| Nexus communicationis remotae | 1411:NO, 1112:NC | ||||
| Currentis aestimata contactus remoti | 220V/0.5A | ||||
Mechanica proprietates
| Conexio terminalium per cochleas | 6-35mm² |
| Torques Cochleae Terminalis | 2.0 Nm |
| Sectio transversalis funis commendata | ≥10mm² |
| Longitudo fili inserendi | XV mm |
| Montatio ferriviae DIN | 35mm (EN60715) |
| Gradus Protectionis | IP20 |
| Domus | PBT/PA |
| Gradus ignifugus | UL94VO |
| Temperatura operandi | 40℃ ~ +70℃ |
| Humiditas relativa operandi | 5%-95% |
| Pressio atmosphaerica operativa | 70kPa~106kPa |