| BY1-12.5-XXX/1(S) 75 150 275 320 385 440 | ||||||||
| IEC Electrica | ||||||||
| Tensio AC Nominalis (50/60Hz) | U₀/Un | 60V | 120V | 230V | 230V | 230V | 400V | |
| Maxima Tensio Operativa Continua (AC) | Ue | 75V | 150V | 275V | 320V | 385V | 440V | |
| Currens Emissionis Nominalis (8/20μs) | In | 20kA | 20kA | 20kA | 20kA | 10kA | 10kA | |
| Maxima Currens Exonerationis (8/20μs) | lmax | 50kA | 50kA | 50kA | 50kA | 50kA | 50kA | |
| Impulsus Fluxus Exonerationis (10/350μs) | claudicans | 12.5kA | 12.5kA | 12.5kA | 12.5kA | 10kA | 10kA | |
| Energia Specifica | W/R | 39kJ/Q | 39kJ/Ω | 39kJ/Ω | 39kJ/Ω | 25 kJ/Ω | 25kJ/Ω | |
| Impetus | Q | 6.25As | 6.25As | 6.25As | 6.25As | Quinque As | Quinque As | |
| Gradus Protectionis Tensionis | Up | 700V | 1000V | 1500V | 1600V | 1800V | 2000V | |
| Tempus Responsionis | tA | <25 ns | ||||||
| Fusus Subsidiarius (max) | 315A/250AgG | |||||||
| Cursus Brevis Circuitus Aestimatio (AC) | lscCR | 25 kA/50 kA | ||||||
| TOV Resistere 5s | UT | 114V | CLXXX | 335V | 335V | 335V | 580V | |
| UT | CLXXXV | 230V | 440V | 440V | 440V | 765V | ||
| TOV 120 min. | Modus | Resistere | Defectus Tutus | Defectus Tutus | Defectus Tutus | Defectus Tutus | Defectus Tutus | |
| Numerus Portuum | 1 | |||||||
| ULElectrical | ||||||||
| Maxima Tensio Operativa Continua (AC) | MCOV | 75V | 150V | 275V | 320V | 385V | 440V | |
| Aestimatio Protectionis Tensionis | VPR | 330V | 600V | 900V | 1200V | 1350V | 1500V | |
| Currens Emissionis Nominalis (8/20 μs) | Ego. | 20kA | 20kA | 20kA | 20kA | 20kA | 20kA | |
| Cursus Brevis Circuitus Aestimatio (AC) | sCCR | 100kA | 200kA | 150kA | 150kA | 150kA | 200kA | |
| Mechanica et Ambientalis | ||||||||
| Ambitus Temperaturae Operativae Ta | -40°F ad +158°F [-40°C ad +70°C] | |||||||
| Humiditas Operativa Permissa RH | 5%…95% | |||||||
| Pressio atmosphaerica et altitudo | 80k Pa…106k Pa/-500m…2000m | |||||||
| Momentum Cochleae Terminalis Mmax | 39.9 lbf · in [4.5 Nm] | |||||||
| Sectio Transversa Conductoris (max) | 2AWG (Solidum, Filum) / 4AWG (Flexibile) 35mm² (Solidum, Filum) / 25mm² (Flexibile) | |||||||
| Montatio | Ferrivia DIN 35mm, EN 60715 | |||||||
| Gradus Protectionis | IP20 (intus) | |||||||
| Materia Domus | Thermoplasticum: Gradus Extinctionis UL94 V-0 | |||||||
| Protectio Thermalis | Ita | |||||||
| Status Operandi/Indicatio Culpae | Viridis bene/Ruber vitium | |||||||
| Contactus Remoti (RC) | Facultativum | |||||||
| Capacitas Commutationis RC | AC:250V/0.5A;DC:250V/0.1A;125V/0.2A;75V/0.5A | |||||||
| Sectio Transversa Conductoris RC (max) | 16AWG (Solidum) / 1.5mm² (Solidum) | |||||||