IEC Electrica
| Tensio AC Nominalis (50/60Hz) | Uo/Un | 120V | 230V | 230V | 230V | 400V |
| Maxima Tensio Operativa Continua (AC) | Uc | 150V | 275V | 320V | 385V | 440V |
| Nomina Currens Exonerationis (8/20)μs) | I。 | 25 kA | ||||
| Maxima Currens Exonerationis (8/20)μs) | lmaximum | 100 kA | ||||
| Impulsus Fluminis Exonerationis (10/350)μs) | ldiabolus | 25 kA | ||||
| Summa Currens Exonerationis (10/350)μs) | lsumma | 100 kA | ||||
| Energia Specifica | W/R | 156 kJ | ||||
| Impetus | Q | 12.5As | ||||
| Gradus Protectionis Tensionis | Up | 1000V | 1500V | 1600 V | 1800V | 2000V |
| Tempus Responsionis | tA | <25 ns | ||||
| Fusus Subsidiarius (max) | 315A gL/gG | |||||
| Cursus Brevis Circuitus Aestimatio (AC) | lscCR | 50 kA | ||||
| TOV Resistere 5s | UT | CLXXXV | 335V | 335V | 335V | 580V |
| TOV 120 min. | UT | 230V | 440V | 440V | 440V | 765V |
| Numerus Portuum | 1 | |||||
Mechanica et Ambientalis
| Ambitus Temperaturae Operativae | Ta | -40°F ad +158°F [-40°Celsiusad +70CelsiusI |
| Humiditas Operativa Permissa | RH | 5%…95% |
| Pressio atmosphaerica et altitudo | 80k Pa...106k Pa/-500m...2000m | |
| Torques Cochleae Terminalis | Mmax | 26.5 lbf-in [3.0 Nm] |
| Sectio Transversa Conductoris (max) | 2AWG (Solidum, Filum)/4AWG (Flexibile) | |
| 35mm² (Solidum, Filum) / 25 mm²(Flexibilis) | ||
| Montatio | Ferrivia DIN 35 mm. EN 60715 | |
| Gradus Protectionis | IP 20 (intus) | |
| Materia Domus | Thermoplasticum: Gradus Extinctionis UL94V-0 | |
| Protectio Thermalis | Ita | |
| Status Operandi/Indicatio Culpae | Viridis bene/Ruber vitium | |
| Contactus Remoti (RC) | Facultativum | |
| Capacitas Commutationis RC | AC: 250V / 0.5A; ABC: 250V / 0.1A; 125V / 0.2A; 75V / 0.5A | |
| Sectio Transversa Conductoris RC (max) | 16AWG (Solidum) / 1.5mm² (Venditum) |
Informationes Ordinis
| Ordo Codex | CL | 275 | 320 | 385 | 440 |
| BY1-25-XXX/4 | 2515041 | 2527541 | 2532041 | 2538541 | 2544041 |
| BY1-25-XXX/4S (cumcontactus remoti) | 2515042 | 2527542 | 2532042 | 2538542 | 2544042 |
Legenda
Linea L/L'
N/N' Neutralis
Terra Protectoria PE
Contactus Signationis S Facultativi
| Dimensiones &Involucrum | |||||
| BY1-25-XXX/3(S) | CL | 275 | 320 | 385 | 440 |
| Dimensiones Unitatis Singulae DIN 43880 | 1 CTN | ||||
| Dimensiones Involucri (A × L × L) | [260×230×320mm] | ||||
| Quantitas Minima Ordinis | 12Unitates | ||||