| Interruptor Circuitus Seriei LQL7-PV | LQL7-PV |
| Gradus quadri fluxus aestimatus (A) | 63 |
Efficacia electrica
| Tensio operativa nominalis Ue (VDC) | 1P: DC250V 2P: DC550V 3P: DC750V 4P: | ||||
| Currens Aestimatus In(A) | 6-10-16-20-25-32-40-50-63 | ||||
| Tensio insulationis aestimata Ui(VDC) | 1P: DC250V 2P: DC550V 3P: DC750V 4P: DC1000V | ||||
| Tensio impactus acta Uimp(kV) | 4 | ||||
| Capacitas frangendi ultima lcu(kA) | 6 | 6 | 6 | 6 | |
| Capacitas frangendi cursus lcs(%lcu) | 75% | 75% | 75% | 75% | |
| Typus curvae | |||||
| Genus itineris | Thermal-magneticus | ||||
| MECHANICA | Valor medius actualis | Viginti milia | |||
| Valor normalis | 8500 | ||||
| ELECTRICUS | Valor medius actualis | 2500 | |||
| Valor normalis | 1500 | ||||
Imperium et indicatio
| Emissio shunt (SHT) | Optio | ||||
| Liberatio tensionis minimae (UNT) | |||||
| Contactus auxiliaris (AX) | |||||
| Contactus alarmis (AL) | |||||
| Actio et Installatio | |||||
| Capacitas filorum (mm²) | In ≤32A, 1~25mm², 1≥40A, 10~35mm² | ||||
| Temperatura ambientis (℃) | -20~70 | ||||
| Altitudo | ≤2000 | ||||
| Humiditas relativa | ≤95% | ||||
| Gradus Pollutionis | |||||
| Ambitus Installationis | Nullus ictus et vibratio manifesta | ||||
| Categoria installationis | Classis III | ||||
| Installatio | Ferrivia DIN Standard | ||||
| Dimensiones (L) × (A) × (Profunditas) | 17.5 | 35 | 52.5 | 70 | |
| H | 80 | 80 | 80 | 80 | |
| Profundus | 71 | 71 | 71 | 71 | |
| Pondus (kg) | 0.12 | 0.24 | 0.36 | 0.48 | |